Interactive Sample Report

This is exactly what you get.

Every ProSight report is interactive, severity-tagged, and built to be opened from any device. Below is a full sample — filter findings, click into one to see how photos, videos, and audio notes are launched directly from the finding itself.

412 Pine St — Sample Report
All (12)
Safety (2)
Major (3)
Minor (5)
Info (2)

Sections

  • Electrical 3
  • Roof 2
  • HVAC 2
  • Plumbing 2
  • Structure 1
  • Exterior 1
  • Interior 1
PHOTO
Safety
Double-tapped breaker in main panel
Electrical · Basement panel · Slot 14
View detail →
PHOTO
Safety
GFCI missing at kitchen counter
Electrical · Kitchen · West wall outlet
View detail →
PHOTO
Major
HVAC service overdue — 12-yr unit
HVAC · Garage split system · Condenser
View detail →
PHOTO
Major
Active moisture at chimney flashing
Roof · North-facing slope · Chimney base
View detail →
PHOTO
Major
Water heater nearing end of service life
Plumbing · Garage · 50gal gas, 11yr
View detail →
PHOTO
Minor
Minor flashing lift at chimney
Roof · South slope
View detail →
PHOTO
Minor
Loose handrail at upper stairs
Interior · Staircase
View detail →
PHOTO
Minor
Caulking degraded — tub surround
Interior · Master bath
View detail →
PHOTO
Minor
Two exterior trim boards rot-stained
Exterior · East fascia
View detail →
PHOTO
Minor
Slow drain — primary bath sink
Plumbing · Master bath
View detail →
PHOTO
Info
Supply pressure 78 psi (within range)
Plumbing · Main supply
View detail →
PHOTO
Info
Foundation — no visible defects
Structure · Slab on grade
View detail →
Anatomy of a Finding

Click any finding — here's what opens.

Each finding launches its own detail view with photos, videos, audio notes, and the inspector's recommendations. All playable directly from the report on PC or mobile — no separate downloads, no external file viewers.

Safety

Double-tapped breaker in main panel

Electrical · Basement panel · Slot 14 · Photo 47 / 312
Video 0:48
Photos 6
🎤
Voice Note 0:22
🔍
Thermal 2

What we found

Two separate circuit conductors landed on a single 20A breaker terminal in the main service panel. This is a code violation and a fire risk — the breaker is rated for a single conductor at each lug.

Recommendation

Have a licensed electrician separate the conductors onto two breakers (or install a listed pigtail). Verify other slots in the panel are not similarly double-tapped.

Inspector note added 2:47 PM Severity: Safety
Designed for Every Device

Open the report where you are.

The same interactive report on every device. Open on your phone in the driveway, pull it up on a laptop at the closing table, share a link with your agent or contractor. Photos, videos, voice notes — all play directly in the browser.

  • Photo galleries with zoom & severity tagging
  • Video walkthroughs of complex findings
  • Inspector voice notes for context
  • Thermal imaging side-by-side with normal photos
  • Share a single link — no app required
  • Works offline once loaded (PWA)
ProSight Report12
Safety
Panel: double-tap
🎤
Safety
GFCI missing
Major
HVAC overdue
Major
Chimney flashing
Minor
Handrail loose
Ready

Get a report like this for your home.

Same interactive viewer, same photo and video depth, same severity tagging. For your home, not a sample.

Mockup · Day 1 · v9 · Sample Report